Legrand 026247 Extended front terminals

Legrand: Extended front terminals (4) - for DPX 630

LEGRAND REF: 026247

Legrand 026245 Sealable terminal shields

Legrand: Sealable terminal shields (2) - for DPX/DPX-IS 630 - 4P

LEGRAND REF: 026245

Legrand 026244 Sealable terminal shields

Legrand: Sealable terminal shields (2) - for DPX 630 - 3P

LEGRAND REF: 026244

Legrand 026230 Insulated shields

Legrand: Insulated shields (3) - for DPX 250/630

LEGRAND REF: 026230

ABB 1SDA101800R1 XT7L M 1250 Ekip Hi-Touch LSIG 1250 4pFF

C.BREAKER TMAX XT7L 1250 FIXED FOUR-POLE WITH FRONT TERMALS AND STORED ENERGY OPERATING MECHANISM AND LEVER OPERATG MECHANISM AND SOLID-STATE RELEASE AC EKIP HI-TOUCH LSIG R 1250

ABB 1SDA101532R1 XT7L M 1250 Ekip M Dip I In=1250A 3p F F

C.BREAKER TMAX XT7L 1250 FIXED THREE-POLE WITH FRONT TERMINALS AND STORED ENERGY OPERATING MECHANISM AND LEVER OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC EKIP M DIP I R 1250

ABB 1SDA101536R1 XT7L M 1250 Ekip M Touch LRIU 1250 3p FF

C.BREAKER TMAX XT7L 1250 FIXED THREE-POLE WITH FRONT TERMINALS AND STORED ENERGY OPERATING MECHANISM AND LEVER OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC EKIP M TOUCH LRIU R 1250

ABB 1SDA101508R1 XT7L M 1250 Ekip Touch LSI In1250A 3p FF

C.BREAKER TMAX XT7L 1250 FIXED THREE-POLE WITH FRONT TERMINALS AND STORED ENERGY OPERATING MECHANISM AND LEVER OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC EKIP TOUCH LSI R 1250

ABB 1SDA101780R1 XT7L M 1250 Ekip Touch LSI In1250A 4p FF

C.BREAKER TMAX XT7L 1250 FIXED FOUR-POLE WITH FRONT TERMINALS AND STORED ENERGY OPERATING MECHANISM AND LEVER OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC EKIP TOUCH LSI R 1250

ABB 1SDA101512R1 XT7L M 1250 Ekip Touch LSIG In1250 3p FF

C.BREAKER TMAX XT7L 1250 FIXED THREE-POLE WITH FRONT TERMINALS AND STORED ENERGY OPERATING MECHANISM AND LEVER OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC EKIP TOUCH LSIG R 1250

ABB 1SDA101784R1 XT7L M 1250 Ekip Touch LSIG In1250 4p FF

C.BREAKER TMAX XT7L 1250 FIXED FOUR-POLE WITH FRONT TERMINALS AND STORED ENERGY OPERATING MECHANISM AND LEVER OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC EKIP TOUCH LSIG R 1250

ABB 1SDA101548R1 XT7L M 1250 EkipG Hi-TouchLSIG 1250 3pFF

C.BREAKER TMAX XT7L 1250 FIXED THREE-POLE WITH FRONT TERMINALS AND STORED ENERGY OPERATING MECHANISM AND LEVER OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC EKIP G HI-TOUCH LSIG R 1250

ABB 1SDA101812R1 XT7L M 1250 EkipG Hi-TouchLSIG 1250 4pFF

C.BREAKER TMAX XT7L 1250 FIXED FOUR-POLE WITH FRONT TERMINALS AND STORED ENERGY OPERATING MECHANISM AND LEVER OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC EKIP G HI-TOUCH LSIG R 1250

ABB 1SDA101516R1 XT7L M 1250 EkipTouch Meas.LSI 1250 3pFF

C.BREAKER TMAX XT7L 1250 FIXED THREE-POLE WITH FRONT TERMINALS AND STORED ENERGY OPERATING MECHANISM AND LEVER OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC EKIP TOUCH MEASURING LSI R 1250

ABB 1SDA101788R1 XT7L M 1250 EkipTouch Meas.LSI 1250 4pFF